Water Testers and testing equipment - IWE Ireland
You are here : Water Testing Equipment > Electrodes Special
All in
stock and available for immediate delivery.
pH & ORP Electrodes - Electrodes Special |
-
| FC911 |
HI1292 |
HI1296 |
 |
 |
 |
| Reference |
Reference |
Reference |
| Double, Ag/AgCl |
Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
Junction |
| Ceramic, single |
Ceramic, triple |
Cloth |
| Electrolyte |
Electrolyte |
Electrolyte |
| KCl 3.5M |
KCl 3.5M + AgCl |
Gel |
| Max Pressure |
Max Pressure |
Max Pressure |
| 0.1 bar |
0.1 bar |
3 bar |
| Range |
Range |
Range |
| pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
pH: 0 to 12 T: -5 to 100°C
(23 to 212°F) |
pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
| Tip Shape |
Tip Shape |
Tip Shape |
| Spheric (dia: 7.5 mm) |
Conic (12 x 12 mm) |
Spheric (dia: 5 mm) |
| Temperature Sensor |
Temperature Sensor |
Temperature Sensor |
| Yes |
Yes |
Yes |
| Amplifier |
Amplifier |
Amplifier |
| No |
Yes |
Yes |
| Body Material |
Body Material |
Body Material |
| PVDF |
Glass |
Titanium cage |
| Cable** |
Cable** |
Cable** |
| Bipolar; 1 m (3.3’) |
7-pole; 1 m (3.3’) |
5-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
Recommended Use |
| Creams, fruit juices, sauces |
Direct soil pH measurement,
soil solution |
Wastewater |
| |
|
|
| HI1297 |
HI1413 |
HI1413 / 50 |
 |
 |
 |
| Reference |
Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
Junction |
| Cloth |
Open |
Open |
| Electrolyte |
Electrolyte |
Electrolyte |
| Gel |
Viscolene |
Viscolene |
| Max Pressure |
Max Pressure |
Max Pressure |
| 3 bar |
0.1 bar |
0.1 bar |
| Range |
Range |
Range |
| pH: 0 to 13 / ORP T: 0 to
80°C (32 to 176°F) |
pH: 0 to 12 T: -5 to 50°C
(23 to 122°F) |
pH: 0 to 12 T: -5 to 50°C
(23 to 122°F) |
| Tip Shape |
Tip Shape |
Tip Shape |
| pH: Conic (3 mm) ORP: Platinum
sensor |
Flat |
Flat |
| Temperature Sensor |
Temperature Sensor |
Temperature Sensor |
| Yes |
No |
No |
| Amplifier |
Amplifier |
Amplifier |
| Yes |
No |
No |
| Body Material |
Body Material |
Body Material |
| Titanium cage |
Glass |
Glass |
| Cable** |
Cable** |
Cable** |
| 7-pole; 1 m (3.3’) |
Coaxial; 1 m (3.3’) |
Coaxial; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
Recommended Use |
Wastewater, municipal water,
water treatment,
swimming pools |
Surfaces, skin, leather, paper,
emulsions |
Skin, scalp |
| |
|
|
| HI1414 |
HI1414/50 |
 |
 |
| Reference |
Reference |
| Single, Ag/AgCl |
Single, Ag/AgCl |
| Junction |
Junction |
| Open |
Open |
| Electrolyte |
Electrolyte |
| Viscolene |
Viscolene |
| Max Pressure |
Max Pressure |
| 0.1 bar |
0.1 bar |
| Range |
Range |
| pH: 0 to 12 T: -5 to 50°C
(23 to 122°F) |
pH: 0 to 12 T: -5 to 50°C
(23 to 122°F) |
| Tip Shape |
Tip Shape |
| Flat |
Flat |
| Temperature Sensor |
Temperature Sensor |
| Yes |
Yes |
| Amplifier |
Amplifier |
| Yes |
Yes |
| Body Material |
Body Material |
| Glass |
Glass |
| Cable** |
Cable** |
| 7-pole; 1 m (3.3’) |
7-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
| Surface, leather, paper, emulsions |
Skin, scalp |
| |
|
| HI62911 |
HI62920 |
HI72911 |
 |
 |
 |
| Reference |
Reference |
Reference |
| Double, Ag/AgCl |
Double, Ag/AgCl |
Double, Ag/AgCl |
| Junction |
Junction |
Junction |
| Teflon® |
Teflon® |
Teflon® |
| Electrolyte |
Electrolyte |
Electrolyte |
| Polymer |
Polymer |
Polymer |
| Max Pressure |
Max Pressure |
Max Pressure |
| 3 bar |
3 bar |
3 bar |
| Range |
Range |
Range |
| pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
pH: 0 to 13 T: 0 to 80°C
(32 to 176°F) |
| Tip Shape |
Tip Shape |
Tip Shape |
| Flat |
Flat |
Flat |
| Temperature Sensor |
Temperature Sensor |
Temperature Sensor |
| Yes |
Yes |
Yes |
| Amplifier |
Amplifier |
Amplifier |
| Yes |
Yes |
Yes |
| Body Material |
Body Material |
Body Material |
| Titanium cage working as
Matching Pin |
Titanium cage working as
Matching Pin |
AISI 316 working as Matching
Pin |
| Cable** |
Cable** |
Cable** |
| 7-pole; 1 m (3.3’) |
7-pole; 2 m (6.6’) |
7-pole; 1 m (3.3’) |
| Recommended Use |
Recommended Use |
Recommended Use |
| Plating baths |
Industrial applications |
Cooling towers, boilers |
| |
|
|
|
Industrial Water Equipment Ltd
2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 14428670
info@industrialwaterequipment.ie
-------------------------------------
124 / 126, North Parade, Matlock Bath,
Derbyshire, DE4 3NS
TEL: +44 (0) 1629 580468
FAX: +44 (0)1629 501055
info@industrialwaterequipment.co.uk
| 24Hr
Helpline - Emergency
Number : 07775 661688 |
Sitemap
| Terms
& Conditions of Sale | Returned
Goods Policy |
Payment
Option

|