HI
983301N • HI 983301N/5 •
HI 983302N - Water-Resistant
EC and TDS Meters
These state-of-the-art meters have
been engineered with a host of features
to suit the aggressive environments
commonly found in agricultural applications.
To make these indicators
ideally suited for growers, the
housings and cable connections have
been sealed against vapor and humidity.
Problems due to low batteries and
battery changes have been solved
with a 12 VDC power supply included
with the meter. You can simply hang
the meter right above the sample
to be monitored or take it with
you for spot checking. Select HI
983301N for TDS measurements with
the common 0.7 TDS conversion factor
(4-4-2) or HI 983301N/5 which uses
a 0.5 conversion factor. Both the
TDS and EC meters come with a probe
specifically made for horticultural
& hydroponics applications.
The probe compensates for temperature
variation automatically, is easy
to clean and is very stable, needing
little maintenance.
HI 983301N is supplied with HI 7634 probe, 12 Vdc adapter, 1500 ppm calibration solution (20 mL), calibration screwdriver and instructions.
HI 983301N/5 is supplied with HI 7634 probe, 12 Vdc adapter, 1382 ppm calibration solution (20 mL), calibration screwdriver and instructions.
HI 983302N is supplied with HI 7632 probe, 12 Vdc adapter, 1413 ?S/cm calibration solution (20 mL), calibration screwdriver and instructions.
|
HI
993301 • HI 993302 - EC / TDS / Temperature Monitors with
Back-lit Display for Agriculture
These indicators from Hanna have
a large, dual-level, back-lit LCD
to give instantaneous readings of
both EC/TDS and temperature even from
a distance. The waterproof EC/TDS
indicators HI 993301 and HI 993302
have been designed to meet the Grower's
need for equipment suited to the aggressive
environments found in agricultural
and hydroponics applications. At startup,
HI 993301 and HI 993302 perform a
self-check to assure proper working
condition. These powerful instruments
also feature a stability indicator
and hold feature to prompt the user
when to take the reading and freeze
the display for easy and accurate
recording. Calibration and temperature
compensation is automatic, while the
EC/TDS conversion factor and temperature
coefficient factor (?) are user adjustable
for application specific measurements.
Choose your EC/TDS indicator according
to the proper EC/TDS ranges for your
application:
· HI 993301: EC - 0 to 3999
?S/cm; TDS - 0 to 2000 ppm
· HI 993302: EC - 0.00 to 20.00
mS/cm; TDS - 0.00 to 10.00 ppt
HI 993301 is supplied complete with HI 7630 EC probe, 1413 ?S/cm calibration solution (20 mL), 12 Vdc adapter and instructions.
HI 993302 is supplied complete with HI 7630 EC probe, 12.88 mS/cm calibration solution (20 mL), 12 Vdc adapter and instructions.
|
HI
983303 • HI 983306 • HI
983307 • HI 983308 - Water-Resistant
EC/TDS Meters with Visual Alarm
Water-resistant conductivity/TDS
meters are Hanna’s reply to
requests of accurate process monitoring
at highly affordable costs with low
maintenance. Four different models
are available to cover all applications.
Each meter is supplied with a direct
2-pin probe and 2 meter (6.6') cable
with a 1⁄2" thread for
flow-thru mounting. The probe has
a temperature sensor to automatically
compensate against temperature changes
from 5 to 50°C (41 to 122°F)
with a ? of 2% per degree. In the
measurement mode, a red LED will warn
the user in the event the reading
is outside of the alarm interval.
A front trimmer allows manual calibration
at 1 point. The electrical circuitry
is tightly sealed inside the water-resistant
enclosure. EC and TDS can be installed
anywhere quickly and easily with the
casings molded hook. The specially
designed casing is stable and will
not roll off a table. The 12 VDC power
supply allows continuous monitoring
over extended periods of time.
HI 983303 is supplied complete with HI 7634/2 probe, 12 Vdc adapter, 1413 uS/cm calibration solution (20 mL), screwdriver and instructions.
HI 983306 is supplied complete with HI 7634/2 probe, 12 Vdc adapter, 1382 ppm calibration solution (20 mL), screwdriver and instructions.
HI 983307 is supplied complete with HI 7632/2 probe, 12 Vdc adapter, 5000 uS/cm calibration solution (20 mL), screwdriver and instructions.
HI 983308 is supplied complete HI 7632/2 probe, 12 Vdc adapter, 6.44 ppt calibration solution (20 mL), screwdriver and instructions.
|
|
Industrial Water Equipment Ltd
2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 15262557
FAX: + 00 353 16865541
info@industrialwaterequipment.ie
-------------------------------------
124 / 126, North Parade, Matlock Bath,
Derbyshire, DE4 3NS
TEL: +44 (0) 1629 580468
FAX: +44 (0)1629 501055
info@industrialwaterequipment.co.uk
| 24Hr
Helpline - Emergency
Number : 07775 661688 |
Sitemap
| Terms
& Conditions of Sale | Returned
Goods Policy |
Payment
Option

|