Backflow Protection Valves

BA2760

backflow preventers

Backflow preventer with controllable reduced pressure zones.

PROTECTION OF DRINKING WATER NETWORKS
PRESSURE PFA 10 bar T°C 65°
Backflow preventer with verifiable reduced pressure zone with funnel attached
CASING : bronze (brass for 1/2 and 3/4)
With male threaded union nuts (except OEM version : 1/2 male threaded union nut)
VALVES : brass and PPO (polyphenylene oxide) or PPA (polyphtalamide
SEALS : silicone and EPDM
SPRING : stainless steel
SPECIAL NOTE : horizontal installation

male/male

DN Ref. U V
1/2 149B 3880 1
3/4 149B 3481 1
1 149B 3082 1
1 1/4 149B 3083 1
1 1/2 149B 3086 1
2 149B 3085 1

BA4760

backflow preventers

Cast iron water filter with a stainless steel strainer and brass drain cock. For protection of pumps, valves, pressure reducing valves, backflow preventers.

PROTECTION OF DRINKING WATER NETWORKS
PRESSURE PFA 10 bar T°C 65°
Backflow preventer with verifiable reduced pressure zone with funnel attached
CASING : cast iron with epoxy coating
VALVES : BA4760 : valve head in DZR brass or bronze and valve seat in PPO or bronze
VALVES : brass and PPO (polyphenylene oxide) or PPA (polyphtalamide
SEALS : EPDM/Silicone
SPRING : stainless steel
SPECIAL NOTE : horizontal installation

with PN10 flanges

DN Ref. U V
21/2 149B 3486 1
3 149B 3097 1
4 149B 3098 1
6 149B 3400 1
8 149B 3401 1
10 149B 3402 1

CA296

backflow preventers

To protect low risk or intermittent risk installations which nevertheless require a backflow prevention system : domestic heating units < 70 Kw, vending machines, certain laboratory equipment... Special versions in M/M and nickel-plated in M/M or F/F

HEATING INSTALLATIONS WITH LESS THAN 70 kW

PRESSURE PFA 10 bar T°C 65°
Backflow preventer with non verifiable reduced pressure zone with funnel attached
CASING : brass
VALVES : POM (polyacetal) and brass
MEMBRANE AND SEALS : NBR (nitrile) and EPDM
SPRING : stainless steel
Female threaded union nuts and drain holder
OPTIONS : threaded male/male version and male/male or female/female nickel-plated versions available on request

female/female

DN Ref. U V
2 1/2 149B 2885 1
3 1/4 149B 2886 1

DB236

backflow preventers

The Pipe interrupter with vent and moving element type DB is a protection device for the fluids of category 4 without downstream counter pressure. This device insures a protection against back siphonage connecting to the atmosphere, however this devices is not made for protection against back pressure. The flow of the water is in a vertical downward direction.

PROTECTION OF DRINKING WATER NETWORKS

Pressure PFA 10 bar T°C 65°
Pipe interrupter with vent and moving element
Casing : PPO (Polyphenylene oxyd)
VALVES : POM (polyacetal) and brass
Membrane : silicone
Ring : POM (Polyacetal)
SPECIAL NOTE : vertical installation

female/female

DN Ref. U V
3/4 149B 3581 1

Y333P

backflow preventers

Cast iron water filter with a stainless steel strainer and brass drain cock. For protection of pumps, valves, pressure reducing valves, backflow preventers.

PROTECTION OF PUMPS, VALVES, PRESSURE REDUCING VALVES, BACKFLOW PREVENTERS

PRESSURE PFA/PS en bar T°C 100°
FILTER : GJL cast iron epoxy coated internal/external (DN40 to 125) GJS ductile iron epoxy coated internal/external (DN150 to 400)
STRAINER : stainless steel
DRAIN COCK : brass 1/2’’
MESH Ø :
DN 1’’1/2 and 2’’: 500 microns DN 3’’ to 8’’ : 1250 microns
DN 2’’1/2 : 800 microns DN 10’’ to 16’’ : 1600 microns

With PN10 flanges

DN
PFA
PS
Cat
Ref.
U
V
mm
water
L1
L2
G1
G2
1 1/2
40
16
16
16
x
x
3.3
149B 3280
1
2
50
16
16
16
x
x
3.3
149B 3281
1
2 1/2*
65
16
16
16
x
x
3.3
149B 3282
1
3**
80
16
16
16
x
x
3.3
149B 3283
1
4
100
16
16
16
x
x
3.3
149B 3284
1
5
125
16
16
16
x
x
3.3
149B 3285
1
6
150
16
13
16
x
x
3.3
149B 3286
1
8
200
10
10
10
x
x
3.3
149B 3287
1
10
250
10
10
10
x
x
1
149B 3288
1
12
300
10
10
10
x
x
1
149B 3289
1
14
350
10
10
x
x
x
1
149B 3288A
1
16
400
10
10
x
x
x
1
149B 3291
1

Y222P

backflow preventers

Cast iron water filter with a stainless steel strainer and brass drain cock. For protection of pumps, valves, pressure reducing valves, backflow preventers.

PROTECTION OF PUMPS, VALVES, PRESSURE REDUCING VALVES, BACKFLOW PREVENTERS

PRESSURE PFA 25 bar T°C 110°
FILTER : brass
STRAINER : stainless steel
DRAIN COCK : brass 1/4’’ (except DN 1/2” : 1/8”)
MESH Ø : 500 microns (except DN 1/2” : 300 microns)

female/female

DN "
REF
UV
1/2
149B 5950
1
3/4
149B 5160
1
1
149B 5161
1
1 1/4
149B 5191
1
1 1/2
149B 5162
1
2
149B 5163
1

 

 

 

Industrial Water Equipment Ltd
2nd Floor, 13 Upper Baggot Street, Dublin 4, Ireland
TEL: + 00 353 14428670

info@industrialwaterequipment.ie

-------------------------------------

124 / 126, North Parade, Matlock Bath, Derbyshire, DE4 3NS
TEL: +44 (0) 1629 580468
FAX: +44 (0)1629 501055

info@industrialwaterequipment.co.uk

24Hr Helpline - Emergency
Number : 07775 661688

 

 

Sitemap | Terms & Conditions of Sale | Returned Goods Policy | Payment Option